Construction Standards

Framing

  Performance Standard Standard Repair
Floor squeak Some noise may be normal on wood floors. Correct any construction defects found.
Uneven floors Floor should not be more than 3/16" out of level within any 48" measurement. Floor slope within any room shall not exceed 2" for every 12'. Make the necessary repairs to correct the condition.
Interior walls should be vertical and plumb Walls may show a horizontal displacement of 1/4" in 8' of rise in wall without a door, or 1/4" in 8' of wall with a door if there is no indication of structural deficiency. Make corrections (e.g., wall should be furred out and drywall replaced or floated.)
Walls should be at 90 degree angles to each other, unless specified otherwise. Walls 10' in length shall not vary more than 1/4" from the perpendicular to the adjoining wall. Make modifications to the wall to improve its appearance, if no structural defects are indicated.
Rough openings for door and windows should be properly dimensioned, plumb, and level The rough opening should be installed according to the manufacturer's recommendations. Assure that openings are structurally sound and cosmetically pleasing.
Warped and twisted studs and ceiling joists Wall and ceiling should be level and should not bulge more than 1/4" in 10'. Make cosmetic corrections where no structural deficiencies are indicated.
Twisted or warped interior posts or beams Any beam or post that twists more than 3/8" in an 8' section is considered unacceptable. Make necessary repairs to correct condition.
Cracked interior beams (finished beams) Cracks in rough interior beams which do not affect structural strength are acceptable if patched or filled. Make necessary repairs.